Improve air conditioning systems for transport vehicles
A matrix of sensors measure air velocity, air temperature, radiant heat flux, and relative humidity, providing rich data points. The automotive manikin system is jointed at the shoulders, hips, knees, elbows, and ankles, and each manikin separates at the waist and neck for easy insertion into any vehicle, and hands are mitten-shaped, with a curved, gripping design to allow for proper positioning onto the vehicle steering wheel.
Highlights
- Air temperature (46 locations):
- 20°C to +70°C measuring range
- Air Velocity (46 locations):
- Omnidirectional 0.1–5.0 m/sec measuring range
- Dual Spectrum Radiant Heat Flux (46 locations):
- Up to 2,000 W/m2 measuring range, 1-20 μm
- Relative Humidity (4 locations): 0 to 95% R.H., non-condensing